Level drops 10 to 30dB when compression kicks in

This is usually normal. The Toneloc is an extreme compressor without adjustable makeup gain, so a significant drop under compression is expected.

  1. Send a very quiet (about -40dBFS or lower) test signal to the Toneloc to test the gain without any compression. If the Toneloc passes roughly unity gain, the Toneloc is working as expected.
  2. If the level drop persists even at very low levels, double check solder joints. See Cleaning Up Solder Joints.

No output, hiss, or erratic compression

  1. Check the orientation of the IC.
  2. Check the orientation and position of all transistors.
  3. Reflow any joints that look cold or "blobby." See Cleaning Up Solder Joints.
  4. If all parts are in the correct place/orientation and reflowing joints doesn't help, the most likely cause is a damaged transistor. Use Parts Request form to request replacement parts.